template image(0) Item / $0
8:00 AM - 4:00 PM EST (Monday-Friday) |Hi Guest, Login! |
Due to Component and Supply Shortages World Wide Due to Component and Supply Shortages World Wide
Altronix AL1012ULACM - Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12VDC @ 10A, FAI, 115VAC, BC400 Enclosure
Altronix AL1012ULACM - Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12VDC @ 10A, FAI, 115VAC, BC400 Enclosure

Altronix AL1012ULACM - Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12VDC @ 10A, FAI, 115VAC, BC400 Enclosure

Manufacturer:Altronix
Manufacturer Part#:AL1012ULACM
Our Part#:AL1012ULACM
Stock Status: Call for Availability
Retail Price:$382.10
Your Savings:$63.37(17%)
Your Price:$318.73

Feature:

Altronix

Feature:

AL1012ULACM

Feature:

Yes

Feature 5

No
Altronix ACM series distribute and switch power to access control systems and accessories. They convert a 115VAC, 60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

Eight (8) independently controlled outputs. 
Output options:  
  • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs;  
  • b) Eight (8) form “C” 5A rated relay outputs;   
  • c) Any combination of the above.
Eight (8) auxiliary power outputs (unswitched). 
Output fuses are rated @ 3.5A.
Filtered and electronically regulated outputs.

Supervision: 
  • AC Fail
  • Battery Fail and Battery Presence.
Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.

Alarm output relay indicates that FACP input is triggered

Fire Alarm disconnect input options:  
  • a) Normally open (NO) or normally closed (NC) dry contact input  
  • b) Polarity reversal input from the FACP signaling circuit.

Built-in charger for sealed lead acid or gel-type batteries.
Instantaneous transfer to stand-by batteries.
UL Listed in the U.S. and Canada.
Lifetime Warranty 