Altronix AL1012ULACMCB - Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12VDC @ 10A, FAI, 115VAC, BC400 Enclosure
Altronix AL1012ULACMCB - Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12VDC @ 10A, FAI, 115VAC, BC400 Enclosure

Altronix AL1012ULACMCB - Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12VDC @ 10A, FAI, 115VAC, BC400 Enclosure

Manufacturer:Altronix
Manufacturer Part#:AL1012ULACMCB
Our Part#:AL1012ULACMCB
Stock Status: Call for Availability
Retail Price:$382.10
Your Savings:$63.37(17%)
Your Price:$318.73

Feature:

Altronix

Feature:

AL1012ULACMCB

Feature:

Yes
Altronix ACMCB series distribute and switch power to access control systems and accessories. They convert a 115VAC, 60Hz input into eight (8) independently controlled 12VDC or 24VDC Class 2 Rated power-limited PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.

Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from the FACP signaling circuit.
The alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
Short circuit and thermal overload protection.

Visual Indicators
  • Red LEDs indicate outputs are triggered (relays energized).
  • Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.

Battery Backup
  • Built-in charger for sealed lead acid or gel-type batteries.
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Battery fail and battery presence supervision (form "C" contact).

Temperature
  • Operating 0ºC to 49ºC (32ºF to 120ºF).
  • Storage - 20ºC to 70ºC ( - 4ºF to 158ºF).
  • Relative Humidity 85% +/- 5%.
BTU/Hr. (approx.)
  • 61 BTU/Hr.