> Altronix AL400UL3 Power Supply Charger, 3 PTC Class 2 Outputs, 5/12/24VDC @ 1.75/1.75/1.5A, 115VAC, BC300 Enclosure
Altronix AL400UL3 Power Supply Charger, 3 PTC Class 2 Outputs, 5/12/24VDC @ 1.75/1.75/1.5A, 115VAC, BC300 Enclosure
Review this item
Add to Wish List
Altronix AL400UL3 Power Supply Charger, 3 PTC Class 2 Outputs, 5/12/24VDC @ 1.75/1.75/1.5A, 115VAC, BC300 Enclosure
0 Review(s)
0
|
Questions about this item? Be the first to ask here.
Manufacturer
:
Altronix
Manufacturer Part#
:
AL400UL3
Our Part#
:
AL400UL3
Stock Status
: Call for Availability
Price
Retail Price:
$342.40
Your Savings:
$58.20
(17%)
Your Price:
$284.20
Quantity
Add to Cart
Feature:
Altronix
Feature:
AL400UL3
Feature:
Yes
Feature 5
No
Description
Accessories
Product Reviews
Documents
Power Supply Charger, 3 PTC Class 2 Outputs, 5/12/24VDC @ 1.75/1.75/1.5A, 115VAC, BC300 Enclosure
Altronix AL400UL3 triple output power supply/charger is designed for use with access control systems and accessories. It converts a 115VAC / 60Hz input into three (3) individually PTC protected 5VDC, 12VDC, and 24VDC regulated outputs.
Features
Input
Input 115VAC, 60Hz, 1.45A.
Output
5VDC, 12VDC, 24VDC simultaneous outputs.
5VDC @ 1.75A continuous supply current.
12VDC @ 1.75A continuous supply current.
24VDC @ 1.5A continuous supply current.
Class 2 Rated PTC protected power-limited auto-resettable outputs.
Outputs are rated @ 2.5A.
Filtered and electronically regulated output.
Short circuit and thermal overload protection.
Battery Backup
Built-in charger for sealed lead acid or gel-type batteries.
Automatic switch over to stand-by battery when AC fails.
Supervision
AC fail supervision (form "C" contacts).
Low battery supervision (form "C" contacts).
Battery presence supervision (form "C" contacts).
Visual Indicators
AC input and DC output LED indicators.
Temperature
Operating 0° C to 49° C (32° F to 120° F).
Storage - 20° C to 70°C ( - 4° F to 158° F).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.)
34 BTU/Hr.
System AC input VA requirement: 166.75