Our office will be closed on Thursday, 11/22. Happy Thanksgiving from TC LifeSafety!Holiday hours may effect shipping dates. Click for More Info
Apollo 55000-215APO, Series 65A Ionisation with flashing LED and Reed Switch

Apollo 55000-215APO, Series 65A Ionisation with flashing LED and Reed Switch

Manufacturer:Apollo America Inc.
Manufacturer Part#:55000-215APO
Our Part#:55000-215APO
Stock Status: 1 week lead time to ship
Retail Price:$35.48
Your Savings:$0.70(2%)
Your Price:$34.78

Feature:

Apollo

Feature:

55000-215APO

Feature:

Yes

Feature 5

Yes

Feature 7

Product Type:Smoke Detector|System Type:Conventional|Detection Type:Ionization|Input Voltage:24VDC|Connection Type:System|Intended Use:Commercial/Industrial|Battery Backup:No|Interconnect:No

1 week lead time to ship

Features

  • Magnetic test switch
  • Flashing LED: The alarm indicating LED flashes when the detector is in a quiescent state
  • Responds well to fast-burning, flaming fires
  • Designed to operate in a variety of environments

Description

The Series 65 Ionization Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chamber and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

A magnetic test switch in the circuit of the detector can be magnetically activated from outside the case to an initiate an alarm condition for test and commissioning purposes.

Technical Data

Detector Part no: 55000-216
Detector Type: Point type smoke detector for fire detection and alarm systems for buildings
Detection Principle: Ionization chamber
Chamber Configuration Twin compensating chambers using one single-sided ionising radiation source
Radioactive Isotope: Americium 241
Activity: 33.3 k Bq, 0.9µCi
Supply wiring: Two wire monitored supply, polarity insensitive
Terminal functions: L1 IN and L2: supply in connections (polarity insensitive)
L1 OUT and L2: supply out connections (polarity insensitive)
?R: remote indicator negative connection
Supply Voltage: 9 to 33V DC
Ripple Voltage: 2V peak to peak maximum at 0.1Hz to 100kHz
Quiescent Current: 20-45µA at 24V
Switch-on Surge Current: 110µA
Alarm voltage: 6 to 33V
Normal Alarm Current: 61mA at 28V
52mA at 24V
18mA at 10V
Alarm indicator: Red, Light Emitting Diode (LED)
Design Alarm Load: 420Ω in series with a 2V drop
Holding Voltage: 6V (min)
Holding Current: 10mA (min)
Minimum Voltage Required to Illuminate Indicator: 12V
Alarm Reset Voltage: 1V
Alarm Reset Time: 1 second
Remote Output Characteristics: Remote is a current sink to the negative line limited to 17mA
Calibration: Factory set to ΔV of 0.8V
Sensitivity: Nominal threshold Y value of 0.7 to EN 54-7: 2000
Temperature Range: Maximum continuous operating temperature: 60°C
Minimum continuous operating temperature: 0°C
Minimum operating temperature: -20°C
(no condensation or icing)
Storage: -30°C to 80°C
Temperature Compensation: Automatic compensation by dual chambers to comply with EN 54-7: 2000 across the operating temperature range
Humidity: 0 to 95% relative humidity
(no condensation)
Atmospheric Pressure: Automatic compensation by dual chambers to maintain sensitivity up to a height of 2000m
Wind Speed: 10m/s maximum
IP rating: 23D in accordance with BS EN 60529
Dimensions: (dia x height) Detector: 100x42mm
Detector in Base: 100x50mm
Weights: Detector: 102g
Detector in Base: 153g
Materials: Detector Housing: White polycarbonate rated V-0 in accordance with UL94
Terminals: Nickel plated stainless steel
The Series 65A Ionization Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chamber and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

You May Also Like...

Recently Viewed Items