- Available in 120VAC and 220VAC with 9VDC Battery Back-Up (Battery Included)
- Horn Frequency 3100Hz (Nominal)
- Nominal 2.5% Sensitivity
- Patented Three Position Test Switch
- On-Site Maintenance Washing Program
- Relays operate on battery back-up
- Quick-Disconnect Wiring Harness
- 90dBA Solid-State Piezo Horn
- Temporal 3 Evacuation Sounding Device (9123 Series)
- 5-to-1 Signal-to-Noise Ratio
- Pulsing LED Sensing Chamber
- Fully Insect Screened
- Red LED pulses every 30 seconds, green LED for AC power on
- Mounting Hardware Adapts to Standard Junction Boxes
- Dust Cover to Prevent Contamination During Installation
- Low or Missing Battery Indicator
The 9000/9003 Series of photoelectric smoke alarms is designed for residential applications and commercia/residential, including homes, apartments, hospitals, hotels and motels, in compliance with UL 217, applicable IBC/IFC Standards and NFPA 72. Available in many different models, the 9120/9123 Series is engineered to virtually eliminate nuisance alarms and deliver outstanding performance wherever reliable fire protection is required. The 9000/9003 Series is provided with a 9 VDC alkaline battery for backup in the event building power is lost. The battery impedance is verified and the detector provides a low or missing battery warning. The Gentex 9000/9003 Series provides an exclusive patented threeposition test feature that simulates a 0.85% and 3.5% actual smokecondition in full compliance with NFPA 72 and UL Standards. Options include self-restoring 135°F integral or isolated heatthermals and Form A/Form C dry contacts for remote annunciation.Tandem interconnection of up to 12 units is available on severalmodels; tandem interconnection of up to 6 units is available on "F"models, which activate the dry contacts from a remote alarmthrough the tandem wire or a local alarm. The 9003 Series provides the temporal 3 evacuation tone as astandard feature. When testing the 9123 Series it may take up to 16seconds longer to go in or out of alarm. - BFP (City of Chicago)
- MSFM Listing #1929
- BS+A/MEA #285-91-E
- CSFM #7257-569:117
- UL 1730 and UL 217 Listed
- CAN/ULC 552-02/553-02 (9000 Series Only)
Model Number | Part Number | Voltage | Local 90dBA Piezo | Integral 135°F Thermal | Isolated 135°F Thermal | Tandem Up To 12 Units | Tandem Up To 6 Units | Form A/C Contacts | 9VDC Battery Back-Up | 9123 | 917-0012-002 | 120VAC | • | | | • | | | • | 9123T | 917-0013-002 | 120VAC | • | • | | • | | | • | 9123H | 917-0014-002 | 120VAC | • | | • | • | | | • | 9123F | 917-0015-002 | 120VAC | • | | | | • | • | • | 9123TF | 917-0017-002 | 120VAC | • | • | | | • | • | • | 9123HF | 917-0016-002 | 120VAC | • | | • | | • | • | • | | | |