- 120VAC/9VDC
- Photoelectric Smoke Sensor and Electrochemical CO Sensor
- UL 217 and UL 2034 Listed
- NFPA72 and NFPA720 Compliant
- Horn Frequency 3100Hz
- Temporal 3 Sounding Pattern for Smoke Annunciation and Temporal 4 Sounding Pattern for CO Annunciation
- Optional Auxiliary Form A/Form C relay contacts (GN-503F Model)
- Quick Disconnect Wiring Harness
- Push Button Self Test Feature
- Push Button Functional Test
- Non-Latching (self restoring)
- Dualink® ? Tandem Interconnect with all Gentex Tandem Capable Alarms
- Low or Missing Battery Indicator
- End of Life Signal Indicating CO sensor has Reached Depletion State
- Mounting Hardware Adapts to Standard Junction Boxes
The GN-503 (120VAC/9VDC) Series of combination photoelectric smoke andelectrochemical sensor carbon monoxide alarms are for use as an evacuation devicein all dwelling units, including but not limited to homes, apartments, hospitals, hotels,motels and other commercial occupancies. The GN-503 Series is listed incompliance with UL 217, UL 2034, for installation per NFPA 720 and NFPA 72.
Available in two models, the GN-503 Series is engineered to virtually eliminatenuisance alarms and deliver outstanding performance wherever reliable smoke andCO protection is required.
The GN-503 Series is provided with a 9VDC alkaline battery for electricalback-up in the event building power is lost. The battery impedance is verified and thealarm provides a low or missing battery warning. The battery drawer provides easyreplacement without removing the unit from the wall or ceiling.
The Gentex GN-503 Series are provided with a self test and functionality test feature.The self test notifies if the smoke/CO alarm is functioning properly or needsattention. The functionality tests that the smoke/CO alarm is operating properly. Theself and functionality tests are in compliance with NFPA 72 and UL Standards.
Features of the combination alarm series include DUALINK® differentiating tonesindicating a smoke alarm (temporal 3) or a CO alarm (temporal 4), tandemcapabilities with all Gentex tandem interconnect capable alarms. Options include aForm A/Form C dry contacts for remote annunciation and connection to a protectedpremises alarm system to provide a supervisory/trouble signal. The GN- 503provides Temporal 3 evacuation tone for smoke alarm and all units provideTemporal 4 tone for CO alarm annunciation. The Temporal 3 evacuation tone forsmoke alarm will take precedence of the Temporal 4 tone for CO alarm.
Operating Voltage | 120VAC, 60Hz |
Operating Current | .045 amps |
Operating Current (Relay Options) | .070 amps |
Operating Ambient Temp Range | 40°F to 100°F |
Alarm Horn Rating | 85dBa at 10 feet |
Auxiliary Relay | 1 Form A & 1 Form C (0.6 amp) |
Size | Diameter: 6.25 in OA (5.75 in. at ceiling) |
Secondary Power Source | Alkaline 9VDC battery Duracell MN 1604 |
CO Sensing Cell | Electromechanical Cell |