Macurco TX-12-AM Gray Housing-Ammonia NH3 Fixed Gas Detector & Controller
Macurco TX-12-AM Gray Housing-Ammonia NH3 Fixed Gas Detector & Controller

Macurco TX-12-AM Gray Housing-Ammonia NH3 Fixed Gas Detector & Controller

Manufacturer:Macurco
Manufacturer Part#:70-2900-0023-3
Our Part#:70-2900-0023-3
Stock Status: Call for Availability
Retail Price:$1,267.54
Your Savings:$443.64(35%)
Your Price:$823.90

Feature:

Macurco

Feature:

70-2900-0023-3

Feature:

Yes

Feature:

783748831203

Feature 5

Yes

Feature 7

Detection Type:Ammonia|Product Type:Detector|Input Voltage:100-240VAC|Intended Use:Commercial/Industrial|Connection Type:Building Wiring,System|Product Status:Current|Battery Backup:No

Features

  • Low-level meter capable of displaying from 0-100 ppm of Ammonia (NH3)
  • Selectable fan and alarm relay activation
  • Meets the NIOSH and OSHA standards for gas exposure
  • 5A SPDT relay controls starters of exhaust fans
  • 0.5A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Supervised system design: internal detector problem will cause fan and alarm relay activation
  • Mounts on a standard 4" x 4" electrical box
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1

Description

The Macurco TX-12-AM is a line voltage, dual relay Ammonia (NH3) detector, controller and transducer. The device utilizes an internal switching power supply that is capable of using line voltage between 100 and 240VAC and 50-60Hz. It features selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of NH3 and provide feedback and automatic exhaust fan control to help reduce NH3 concentrations in industrial refrigeration, warehouses, hockey rinks or other commercial applications.

The TX-12-AM is a low level meter capable of displaying from 0-100 ppm of Ammonia and is factory calibrated and 100% tested for proper operation, but can also be calibrated in the field.

The TX-12-AM meets the NIOSH (National Institute for Occupational Safety and Health) and OSHA (Occupational Safety and Health Administration) standards for gas exposure.

Specifications

Power 100-240VAC (50 to 60Hz)
Connections Plugs/Terminals
Current 1.0A max
Fan Relay 5A, 240VAC, pilot duty, SPDT, latching or non-latching
Fan Relay Actuation Selectable at diS (disable), 15, 20, 25 (default), 30, 35, 40, 45, 50, 55, 60, 65, 70, or 75 ppm NH3
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Min. Runtime Settings 0 (default), 3, 5, 10 or 15 minutes
Alarm Relay [email protected], 60VA
Alarm Relay Actuation Selectable N.O. (default) or N.C.
Alarm Relay Settings diS (disable), 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75 (default), 80, 85, 90, 95 or 100 ppm NH3
Current Loop 4-20 mA for 0-100 ppm NH3, selectable to off or on (default)
Buzzer 85dBA at 10 feet, selectable to off (default) or on
Digital Display 3 digit LED selectable to off (default) or on
Operating Environment 0°F to 125°F (-18°C to 52°C). 10 to 90% RH
Operating Altitude Up to 5,000m (16,404 feet)
Mounting Box 4" x 4" electrical box (not included)
Size 4½" x 4" x 2¾" (11.4 x 10.2 x 7 cm)
Shipping Weight 1 pound (0.45 kg)
Color Dark Gray
Accessories designed for use with this product - To add any of these accessories to your order, simply fill in the quantity you want and click the large "Add to Cart" button above
 
 

You May Also Like...

 
 
 

Recently Viewed Items