template image(0) Item / $0
8:00 AM - 5:00 PM EST (Monday-Friday) |Hi Guest, Login! |
Macurco MA-TX6ND, Nitrogen Dioxide Detector
Macurco MA-TX6ND, Nitrogen Dioxide Detector

Macurco MA-TX6ND, Nitrogen Dioxide Detector

Manufacturer:Macurco
Manufacturer Part#:70-2900-0004-2
Our Part#:MA-TX6ND
Stock Status: In Stock
Retail Price:$565.69
Your Savings:$67.89(12%)
Your Price:$497.80

Feature:

Macurco

Feature:

MA-TX6ND

Feature:

Yes

Feature:

783748825103

Feature 5

Yes

Features

  • 12-24VAC or 12-32VDC input
  • 5A SPDT Fan control relay
  • 0.5A N.O. or N.C. Alarm Relay
  • Selectable Fan and Alarm Relay Actuation Settings
  • Digital Display (0-20ppm of NO2), Internal Buzzer
  • Coverage Area: 5000 sq. ft.
  • 4-20mA current loop

Description

The TX-6-ND is a low voltage, dual relay Nitrogen Dioxide (ND) detector, and an automatic ventilation controller. The TX-6-ND uses a microcomputer-controlled, electronic system to measure the concentration of Nitrogen Dioxide, actuate relays and provide a 4-20mA output. The TX-6-ND has a field replaceable, electrochemical sensor (expected life of 2+ years) and optional gas test and calibration kits. The TX-6-ND is a low-level meter capable of displaying from 0-20ppm of Nitrogen Dioxide

Specifications

  • Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC
  • Current @ 24 VDC: 75 mA in alarm (two relays), 50 mA (fan relay only) and 23 mA stand by
  • Shipping Weight: 1 pound (0.45 kg)
  • Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
  • Color: Dark gray
  • Connections: plugs/terminals
  • Mounting box: (not included) 4x4 electric
  • Fan relay: 5 A, 240 VAC, pilot duty, SPDT
  • Fan relay actuation: selectable at dIS (disabled) 0.5, 0.7, 1.0, 1.2, 1.5, 1.7, 2.0, 2.2, 2.5 (default), 2.7, 3.0, 3.2, 3.5, 3.7, 4.0, 4.2, 4.5, 4.7, 5.0 ppm
  • Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutesFan Minimum Run Time settings are 0 (default), 3, 5, 10 or 15 minutes
  • Fan relay latching or not latching (default) selectable
  • Alarm relay: 0.5A 120 V, 60 VA
  • Alarm relay actuation: selectable N.O. (default) or N.C.
  • Alarm relay settings: dIS, 1, 2, 3, 4, 5 (default), 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20 ppm
  • Current Loop: 4-20 mA for 0-20ppm NO2, selectable to off (default) or on
  • Buzzer: 85 dBA at 10cm settable to off (default) or on
  • Digital display: 3 digit LED selectable to off (default) or on
  • Operating Environment: 0 ° F to 125 ° F (-18 ° C to 52 ° C). 10 to 90% RH noncondensing